Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 03/24/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 03/20/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) NO CHANGE 2) ROOF NAIL OK BUT CANNOT APPROVE UNTIL SUPPORT STRUCTURE IS OK |
| 03/14/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) EXPOSE FOOTINGS ON SOUTH WALL AND WEST WALLS TO A DEPTH OF 12" BELOW GRADE 2) PROVIDE PROOF OF FOOTINGS UNDER POSTS ON INTERIOR BY DRILLING 1/2" X 14" DEEP HOLES NEXT TO EACH POST 3) RAFTERS CANNOT BEAR ON FACIA MUST BEAR ON 4 X 14 BEAM PER PLAN 4) SOUTH WALL MUST HAVE 4 X 12 BEAM 5) UNTREATED WOOD CANNOT BE IN CONTACT WITH CONCRETE 6) POSTS MUST HAVE 1" SEPARATION TO CONCRETE |
| 03/07/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) ROOF COVERING INSTALLED PRIOR TO INSPECTION 2) BANGED ROOF FROM BELOW W/BEDROOM HANGEL. NUMEROUS PLACES WHERE SHEATHING CAN BE LIFTED ABOVE JOISTS. RE-NAIL ROOF 3) 01005 FLOORS PRIOR TO EXCAVATION LAYOUT. AND REBAR INSP. |