Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/14/2004 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 10/06/2003 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) #2 NOT DONE |
| 09/30/2003 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) WALL OSB NOT NAILED OFF UNDER ALL WINDOWS 2) 1 ROW OF NAILING MISSED ON NORTH END ROOF PLYWOOD 3) SHEETS OF OSB THAT ARE LESS THAN 24" WIDE, AT BOTH SIDES OF THE RIDGE, MUST HAVE H CLIPS OR BLOCKED PER PENDICULAR TO TRUSSES. (ALMOST WENT THROUGH WALKING ON THEM) 4) OVER FRAME AREA, AT SOUTH END OF ROOF, HAS NO PLAN DETAIL. AT PRESENT, THE CENTER SPACING IS INADEQUATE AND THERE IS NO BOTTOM PLATE ATTACHED TO THE OLD ROOF, FOR THE NEW RAFTERS TO ATTACH TO NOTE: NO FURTHER INSPECTIONS UNTIL PERMIT AND PLAN CHANGES MADE REGARDING ADULT CARE HOME |