Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM00888
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/31/2003 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*/ 1) PLUMBING INTERMEDIATE AND OVER HEAD-OK | |
| 07/24/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK 2) P.O.C. OF NEW BLDG. SEWER TO EXISTING BLDG 3) SEWER IS OK AS NOTED ON PLAN | |
| 06/30/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) ACID WASTE DILUTION TANK INSTALLED PER PLAN 2) FUSED INLET-ABS OUTLET WITH VENT-OK 3) OK TO COVER | |
| 06/25/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) ROOMS #27-32 ? DWV OK, COPPER OK, GAS OK 2) OK TO COVER THIS AREA | |
| 06/24/2003 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000* 1) GAS IN RM #28 & #32 OVERHEAD TO MECH ROOM OK REMEMBER GAS GAUGES TO BE IN 1/10 18 INCREMENTATION. 2) NO TEST ON FUE AT ADEL CO. ON FOOT VENT FOR ISLAND SINK. | |
| 06/18/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) ABS DWV THRU ROOF AND COPPER PIPING IN ROOMS #17 THRU #20 OK, OK TO COVER AND ELECTRIC WATER COOLER IN #22A | |
| 06/11/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) ABS DWV THRU ROOF AT BATHROOM #11-2 SINKS IN #14 AND BAR SINK IN ROOM #5-OK WATER TEST THRU ROOF-OK 2) COPPER IN SAME AREA OK 3) CLOSET PLANGE OK 4) OK TO COVER SUBJECT TO RELOCATION OF COND DRAIN | |
| 06/09/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) DRINKING FOUNTAIN UNDERGROUND ABS-OK. THIS COMPLETES UNDERGROUND | |
| 06/05/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*/ 1) YOU HAVE 3 LEAKD TO ADD 03005 PLUMBING ROUGH/SOIL TO YOUR PERMIT 2) CONDENSATE MAY NOT TERMINATE IN A SINK TAIL PIECE CODE ALLOWS FOR A DIRECT CONNECTION TO A LAVATORY TAIL PIPE AND A WASTE AND OVERFLOW ON A TUB ONLY 3) PLAN APPROVED IN ERROR | |
| 05/14/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*PLEASE HAVE 03005 PLUMBING ROUGH/SOIL ADDED TO PERMIT 2.) ABS DWV UNDERGROUND FOR BATHROOM #11, 2 SINKS IN #14 AND BARSINK IN ROOM 5 OK TO COVER WATER TEST ONE RISER TO TEN FEET. |