Permit: T03CM00881

Parcel: 12214007B

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
08/13/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*/ CORRECTIONS ARE OK.
08/12/2003 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*/ 1) BOND A/C DISCONNECT ENCLOSURES 2) TIGHTEN LOOSE SEAL TITE FITTINGS 3) FILL UNUSED OPENINGS IN DISCONNECT 4) WE HAVE MULTIPLE TERMANATIONS AT GROUND LUG 5) A PERMANENT ADDRESS LABEL IS NEEDED AT SERVICE 6) OUTSIDE LIGHTS TO HAVE A JUNCTION BOX AS PER MANUFACTURERS PAPER WORK. M/C CABLE TO BE TERMINATED 7) FINISH #2 AND 4 OF PREVIOUS INSPECTION
08/08/2003 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*/ 1) FINISH EXTERIOR LIGHTING 2) CORRECTLY IDENTIFY CONDUCTORS 200.7 3) AN APPROVED EXTENDER RING IS NEEDED AT BATH TILE 4) REJECTION PINS ARE NEEDED FOR SERVICE DISCONNECT 5) A DISCONNECTING MEANS IS NEEDED FOR WATER HEATER 6) PLEASE REVISE PLANS FOR A/C'S