Permit: T03CM00880

Parcel: 116273910

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T03CM00880

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/12/2004 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
02/11/2004 ELECTRIC - FINAL Denied IVRS - Inspection 0999*SECURE OUTLETS AT KITCHEN COUNTER
02/06/2004 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1) INSTALL COVER AT ENTRY GFCI 2) ID SERVICE PANEL AT NON-WATER BOND 3) SECURE OUTLETS AT KITCHEN COUNTER 4) EXCESSIVE WATER PRESSURE 5) INSTALL STAND OFF AT SOFT WATER DRAIN 6) INSTALL DRIP LEG AT FURNACE 7) KITCHEN SINK AND LAUNDRY TUB REQUIRE 1 1/2" TRAPS AND ARMS 8) INSTALL DRAIN AT FRONT WALK 9) 3-SCREW FLUES IN GARAGE 10) REMOVE TAPE CLOSING OFF B-VENT 11) SMOKE DETECTORS PLACED INCORRECTLY IN TWO BEDROOMS WEST OF KITCHEN 12) NOTE: ALSO PROVIDE STUCCO CERTIFICATE