Permit: T03CM00868

Parcel: 141171950


Addresses:

8150 S WOODFROST WY

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/12/2003 FRAMING Approved IVRS - Inspection 0000*
05/09/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) NAIL PROTECT ELECTRIC IN KITCHEN WITHIN 1 1/4 FROM EDGE OF STUD 2) STUD BEHIND TUB AT MASTER BATH OVER NOTCHED 3) SEE #9 FROM LAST INSPECTION 4) SEE #7 PREVIOUS INSPECTION 5) SEE #6 LAST INSPECTION 6) REPLACE MID HEIGHT BLOCKING AT GARAGE SHEARWALL 7) DWV'S AND WATER LINES PASSED TEST
05/07/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) REAR WATER LINE HOSES BIB LINES 2) SECURE WATER LINES AT TUB SECURE STUD AT DIVERTER NOTCHED TO DEEP AND TUB LINES 3) PULL STAPLE AT KITCHEN DIRTY ARM, MAKE SURE ITS NOT IN THE PIPE 4) BANG PLATE WATER LINES SOUTH BATH, A.B.'S 5) STRAIGHTEN CRIPPLES REAR BEDROOM 6) DUCT HANGING FROM CEILING S/FRONT BEDROOM 7) BANG PLATE VENT TOP PLATE SMALL CLOSET SOUTH 8) GAS TEST HOLDING AT 15 POUNDS 9) EXHAUST FAN DAMPERS NOT WORKING 10) NEED DWV TEST
05/06/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) COMPLETE LATH