Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/12/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 05/09/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NAIL PROTECT ELECTRIC IN KITCHEN WITHIN 1 1/4 FROM EDGE OF STUD 2) STUD BEHIND TUB AT MASTER BATH OVER NOTCHED 3) SEE #9 FROM LAST INSPECTION 4) SEE #7 PREVIOUS INSPECTION 5) SEE #6 LAST INSPECTION 6) REPLACE MID HEIGHT BLOCKING AT GARAGE SHEARWALL 7) DWV'S AND WATER LINES PASSED TEST |
| 05/07/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) REAR WATER LINE HOSES BIB LINES 2) SECURE WATER LINES AT TUB SECURE STUD AT DIVERTER NOTCHED TO DEEP AND TUB LINES 3) PULL STAPLE AT KITCHEN DIRTY ARM, MAKE SURE ITS NOT IN THE PIPE 4) BANG PLATE WATER LINES SOUTH BATH, A.B.'S 5) STRAIGHTEN CRIPPLES REAR BEDROOM 6) DUCT HANGING FROM CEILING S/FRONT BEDROOM 7) BANG PLATE VENT TOP PLATE SMALL CLOSET SOUTH 8) GAS TEST HOLDING AT 15 POUNDS 9) EXHAUST FAN DAMPERS NOT WORKING 10) NEED DWV TEST |
| 05/06/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) COMPLETE LATH |