Permit: T03CM00851

Parcel: 110033510

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM00851

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/05/2003 FRAMING Approved IVRS - Inspection 0000*
07/30/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) PLAN MUST BE ON SITE FOR RE-INSPECT 2) REMOVE ALL INSULATION FROM AFFECTED AREAS
07/23/2003 FRAMING Denied IVRS - Inspection 0999* 1) 4 HD HTT22 EPOXY SET BOLT. 2) MISSED HTTP AT SHEARWALL E OF GARAGE DOOR 3) SECURE CEILING BOX IN MASTER CLOSET. 4) EXTEND COMBUSTION AIR DUCT AT FURNACE ROOM TO WITHIN 12" OF FLOOR. 5) SECURE WATER LINES IN 1ST FLOOR BATH.