Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/02/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/29/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) BANG PLATE WIRES AT NORTH EAST CORNER OF GARAGE 2) SHIM PATIO DOOR TRIMMER AND ALL HEADERS WHERE NEEDED 3) SEAL FIRE BLOCKING IN KITCHEN PASS THROUGH AND DOORWAY CHASES 4) CORRECT NAILS/STAPLES BEHIND HOMERUNS. STAPLE IN 220 LINE BEHIND BLOCK |