Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM00820

Parcel: 141303150


Addresses:

6390 S WHEATON DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM00820

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/18/2003 FRAMING Approved IVRS - Inspection 0000*
04/16/2003 FRAMING Denied IVRS - Inspection 0925*/ 1) #925 THERE IS NO PLAN OR JOB INSPECTION CARD ON SITE
04/15/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION SHEAR (OSB) THAT'S ABOVE GARAGE WALL AT THE FURNACE PLEN-AREA. HAS NO BACKING OR ON CENTER VERTS 2) ONE HEADER INSTALLED AT INTERIOR BEARING, TRUSS SITS ON TOP OF IT, BEARING NEED TRIMMERS-1,911 POUNDS AT THAT PT
04/14/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*