Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM00820
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/18/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
04/16/2003 | FRAMING | Denied | IVRS - Inspection 0925*/ 1) #925 THERE IS NO PLAN OR JOB INSPECTION CARD ON SITE | |
04/15/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) FROM LAST INSPECTION SHEAR (OSB) THAT'S ABOVE GARAGE WALL AT THE FURNACE PLEN-AREA. HAS NO BACKING OR ON CENTER VERTS 2) ONE HEADER INSTALLED AT INTERIOR BEARING, TRUSS SITS ON TOP OF IT, BEARING NEED TRIMMERS-1,911 POUNDS AT THAT PT | |
04/14/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |