Permit: T03CM00819

Parcel: 141301840

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM00819

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/10/2003 FRAMING Approved IVRS - Inspection 0000*
04/08/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) SHEAR PANEL NOT NAILED TO ROOF MISSED AT ROOF NAIL INSPECTION BUILD SHEAR PER PLAN ON NEXT HOUSE 403/SD 2) NAIL SHEAR PANELS TO DOUBLE TOP PLATE 3) NEED HEADER SIZE GARAGE MAN DOOR, NOT ON HEADER SCHEDULE 4) SECURE WATER LINES AT, AT FIREPLACE, INSULATION 5) NO GAS PRESSURE 6) BLOCK TRUSSES A BAY WINDDOW 7) NO DWV TEST 8) TUB BACKING, NORTH TUB 9) FIREPLACE FIRE BLOCK