Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/01/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/30/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) 935 A REFEE HAS BEEN ASSESSED FOR THIS INSPECTION 2) SEE INSPECTION DATED 4/29/03 NOTHING DONE, HOUSE BEING SHEET ROCKED |
| 04/29/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SAN-TEE IN HALL WAY ON HORIZONTAL, WILL NEED TO RETEST VENTS 2) MOVE ELECTRICAL WIRE AWAY FROM FURNACE IN ATTIC AND ROMEX AWAY FROM CAN LIGHT UPSTAIRS ABOVE 3) OK TO INSULATE |
| 04/28/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NAIL PROTECT WATER LINE AT WATER HEATER PLATFORM 2) DWV'S FAILED TEST 3) USE PROPER NAIL PROTECTION AT DRYER VENT 4) SAN-TEE NOT ALLOWED ON THEIR SIDE 5) BLOCK RETURNS AT HALL AND MASTER BEDROOM 6) RE-ROUTE ROMEX FOR JACUZZI GFCI 7) MOVE ELECTRICAL WIRES AWAY FROM CAN LIGHTS AND NAIL PROTECT WITHIN 1 1/4" FROM EDGE OF STUD 8) PROVIDE HEADER AT KITCHEN BEARING WALL |