Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/09/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/03/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) OK TO INSULATE #5 SHEAR BOTH SIDES OF GARAGE TO HOUSE, ADD PLYWOOD ABOVE DROP ON GARAGE SIDE 2) ADD STUDS REAR BATH 24" O.C. WALLS INSUALTE TUB |
| 04/01/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CENTER CONDENSATE 2) INSULATE BEHIND TUB 3) ACCESS TO TUB MOTOR (JACUZZI) 4) SECURE WATER SOFTNER DRAIN TUBE ABOVE WASHER TRAY, GAS TEST OK 5) NEED STUCCO STOP AT REAR COL 5) NEED DWV WATER TEST |
| 03/28/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SEAL ALL PENETRATIONS AT LATH EXTERIOR 2) SECURE TRAP ARM IN KITCHEN PONY WALL 3) NAIL PROTECT ELECTRICAL TOP PLATE GARAGE WITHIN 1 1/4" FROM EDGE OF STUD 4) FIRE BLOCK MISSING AT MECHANICAL STAND 5) USE PROPER NAIL PROTECTION FOR DRYER VENT 6) STOPPED INSPECTION, HAVE SUPERVISOR WALK HOUSE BEFORE RECALL |