Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T03CM00774
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/20/2003 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000* | |
02/20/2003 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection 0000*SOME SWITCHES NOT FRAMED CALL WHEN COMPLETE. | |
02/18/2003 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0145*/ 1) IN WALLS FRAMED WITH 2 X 2 METAL STUDS: THE FACE OF THE STUD MUST BE " BANG PLATED" AT THE POINT WHERE MC CABLE IS RUN THROUGH A SHED HOLE. THIS IS REQUIRED AT ANY POINT WHERE THE MC CABLE WILL BE AT 1 1/4" OR LESS FROM IT'S OUTER SURFACE TO THE SURFACE OF THE STUD. BOTH SIDES. CORRECT AND RECALL INSPECTIONS |