Permit: T03CM00765

Parcel: 13212020J

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
01/07/2004 BUILDING - FINAL Approved IVRS - Inspection 0000*
01/05/2004 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) WATER HEATER T & P LINE MUST EXHAUST DOWN 2) SEWER LEAK AT CLEANOUTS. NOT CONNECTED TO SEWER 3) INSTALL THREADED CAPS ON ALL CLEANOUTS 4) ANTI-SIPHON VALVES REQUIRE ON HOSE BIBS 5) PAINT AB'S PLASTIC VENTS ON ROOF 6) GARAGE/OUTSIDE GFCI INOPERABLE 7) ROMEX NOT ALLOWED IN KITCHEN CABINET 8) EXCESS OF 24" FROM CABINET EDGE TO KITCHEN GFCI 9) RANGE REQUIRES 4 WIRE OUTLET 10) NO ATTIC ACCESS