Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM00765

Parcel: 13212020J

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/15/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/13/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) STRAP BEAMS AT BEARING POINTS 2) FILL IN SOLIDLY UNDER GIRDER TRUSSES AT BEARING POINTS 3) INSTALL BANG PLATES EXTERIOR PLATES AT PLUMBING CUT OUTS 4) NO PLANS/PERMIT-TRUSS DRAWINGS 5) STOPPED INSPECTION