Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM00744

Parcel: 137082630


Addresses:

5625 S LIBERTY AV

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
03/09/2004 BUILDING - FINAL Approved IVRS - Inspection 0000*
02/10/2004 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) CUT SEWER CLEANOUT TO GRADE 2) LABEL ELECTRIC PANEL CIRCUITS SERVED 3) POST ADDRESS NUMBERS ON HOUSE 4) COMPLETE GRADING TO SLOPE AWAY FROM HOUSE 5) INSTALL RECEPTACLES UNDER SINK 6) MAINTAIN MINIMUM 6" CLEARANCE FRONT OF FURNACE 7) INSTALL CLEAN OUT UNTO SINK 8) ELEVATE AND SECURE DISHWASHER DRAIN HOSE 9) INSTALL VACCUM BREAKER HOSE BIBS 10) INSTALL GAS COCK AND PLUG AT DRYER AND RANGE 11) NEED ACCESS INTO REAR UTILITY ROOM 12) NEED INSULATION AND STUCCO CERTIFICATES FROM INSTALLERS 13) STOPPED INSPECTION 14) INSTALL DRIP LEG GAS LINES FURNACE AND WATER HEATER PIPING 15) INSTALL DOUBLE WALL VENT PIPE FURNACE FLUE