Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/29/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 09/16/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) TIGHTEN ALL NUTS ON BOLTS 2) UNCOVER GROUND WIRES ATTACH GAS BOND 3) 03050 PLUMBING GAS PRESSURE TEST DOES NOT MATCH PLAN SUBMIT AS BUILT FOR APPROVAL 4) FLUE PIPE MUST PROTRUDE IN FURNACE ROOM CEILING |
| 08/26/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) INSTALL BANG PLATES ALL PENETRATIONS THROUGH WOOD 2) PROVIDE WATER TEST DWV 3) 1" CLEARANCE FLUE PIPE TO WOOD 4) CUT OFF BOLTS CARPORT SLAB 5) WILL HAVE TO FIRE-RATE OVER HANG SOUTH SIDE |
| 08/15/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE WATER TEST ON DWV 2) PROVIDE FIRE STOP AT DOUBLE WALL AT BATH 3) PROVIDE 1" CLEARANCE AT FLUE VENT FROM ANY COMBUSTIBLES 4) STUCCO MESH NOT IN |
| 07/16/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |