Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T03CM00733
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/24/2004 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection 0000* | |
12/31/2003 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection 0000* PERIMETER OK TO POUR | |
12/30/2003 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection 0999* STUB OUT FOR DETAIL 1/2 AT INTERSECTION OF FOOTING. 2/2. PARTY WALL SEC 4/2 CALL FOR #5 @ 16" OC. PUT PORCH POST FOOTING 5/2 WHERE REQUIRED. | |
12/15/2003 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection 0999* CUT BOTTOM OF FOOTING LEVEL & STEP IT WHERE NEEDED, CLEAN OUT FOOTING. REMOVE PORTIONS OF OLD FOOTINGS FROM NEW FOOTINGS. REBAR MUST BE CLEAN OF MUD. REBAR CANNOT TOUCH FOOTING BOX OR SIDES. NEED MORE REBAR ON EACH FACE OF STEM. SEE 2 ON 2. MISSING SOME FOOTINGS. FOOTINGS NOT 12" THICK. INTERSECTING FOOTINGS NEED REBAR LAP.(CONT) PARTY FOOTING WRONG SEC 4 ON 2 |