Permit: T03CM00730

Parcel: 12107136B


Addresses:

6064 E PIMA ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
02/24/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*
02/21/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) INSTALL ADDITIONAL AIR SUPPLY IN HOT WATER HEATER CLOSET DOOR 2) PROTECTION FOR CIRCUIT WIRES EXITING SUBPANEL 3) PERIMETER WALL OUTLETS NEED GFI PROTECTION 4) NEED TRAP INSTALLED ON A/C CONDENSATE LINE 5) NEED GAS PRESSURE TEST 6) PAINT PLUMBING VENTS ON ROOF
02/20/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) ANTI-SIPHON DEVICES REQUIRED AT EXTERIOR HOSE BIBS 2) ARRIVED AT 12:15 PM, NO ANSWER