Permit: T03CM00728

Parcel: 140374320


Addresses:

7024 S DUNNOCK DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/14/2003 FRAMING Approved IVRS - Inspection 0000*
04/11/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) RED HEADS LOOSE THROUGHOUT 2) 4 X 10 CONT. FLUSH NO PER PLAN 3) 2 X 8 LEDGER ABOVE LANDING AT STAIRS MISSING 4) COMPLY WITH DETAIL 49 PAGE AD3 5) ROMEX HANGING ON LAUNDRY ROOM
04/09/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE 1" CLEARANCE AT WATER HEATER FLU FROM COMBUSTILBES AND A FIRE PROOF COLLAR TO 2ND FLOOR 2) THA422 FLOOR TRUSS HANGER NOT INSTALLED AS PER MANUFACTURERS INSTRUCTIONS 3) ANCHOR BOLT NUTS LOOSE THROUGHOUT 4) HOLDOWN AT ENTRY NOT TIGHT 5) LUS 48 AND LTHA 422 AT STAIR AREA USED IN WRONG AREAS 6) LUS 48 MISSING ENTRY WAY 7) STOPPED INSPECTION. HAVE SUPERVISOR WALK HOUSE BEFORE RECALL