Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/27/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 03/19/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) FRONT DOOR HOLDOWN MUST HIT TWO STUDS. WILL NEED SPECIAL EPOXY INSPECTION, SAME WITH HOLDOWN NORTH SIDE OF HOUSE. UNDER WINDOW-DETAIL SD/4 2) EXTERIOR STRAPS MISSING NAILS AND REQUIRED AT EVERY OTHER STUD 3) COMPLY WITH DETAIL 6B/SD1 AND DETAIL 1/SD2 4) REPLACE HILTI PINS 5) STUDS MISSING AT DOUBLE GIRDER TRUSS IN GARAGE 6) PROVIDE TRUSS CALCS 7) WALKED HOUSE WITH FRAMER |