Permit: T03CM00728

Parcel: 140374320


Addresses:

7024 S DUNNOCK DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/27/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
03/19/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) FRONT DOOR HOLDOWN MUST HIT TWO STUDS. WILL NEED SPECIAL EPOXY INSPECTION, SAME WITH HOLDOWN NORTH SIDE OF HOUSE. UNDER WINDOW-DETAIL SD/4 2) EXTERIOR STRAPS MISSING NAILS AND REQUIRED AT EVERY OTHER STUD 3) COMPLY WITH DETAIL 6B/SD1 AND DETAIL 1/SD2 4) REPLACE HILTI PINS 5) STUDS MISSING AT DOUBLE GIRDER TRUSS IN GARAGE 6) PROVIDE TRUSS CALCS 7) WALKED HOUSE WITH FRAMER