Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM00712
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/23/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
04/22/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) BLOCK AND NAIL OFF 4 SIDES OF ROOF OSB THAT ONLY COVERS 1 TRUSS BAY (2 TRUSSES) OR REPLACE OSB TO COVER 3 TRUSSES 2) EAST PLANE OF FRONT GABLE HAS OSB NOT NAILED OFF 3) MISSING UPPER STUD CLIP JUST EAST OF GARAGE DOOR 4) STRAP DOWN FRONT UPPER GABLE TRUSS, AND COMMON RAFTER THAT IS OVER FRAMED ABOVE GARAGE WEST WALL 5) REPLACE SHORT METAL BRACE IN GARAGE WEST WALL 6) STRAP WEST END OF ENTRY 4 X 6 GIRDER AND FINISH NAILING H2.5'S ABOVE IT | |
04/07/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) NOT READY |