Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/18/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/17/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0950*/ 1) SUPPORT 1/2" GAS LINE AT 6' ON CENTER 2) FIRE BLOCK MECHANICAL COPPER CHASE 3) ANCHOR BOLTS MISSING KITCHEN AND BEDROOM 4) GROUND ALL METAL ELECTRIC BOXES 5) INSTALL BUSHINGS OR ROMEX CLAMPS ON KNOCKOUTS 6) KITCHEN SINK REQUIRES VENT TO ROOF, SEE PLAN 7) STOPPED INSPECTION TO MANY ITEMS |