Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/18/2003 FRAMING Approved IVRS - Inspection 0000*
04/17/2003 FRAMING Denied IVRS - Inspection 0950*/ 1) SUPPORT 1/2" GAS LINE AT 6' ON CENTER 2) FIRE BLOCK MECHANICAL COPPER CHASE 3) ANCHOR BOLTS MISSING KITCHEN AND BEDROOM 4) GROUND ALL METAL ELECTRIC BOXES 5) INSTALL BUSHINGS OR ROMEX CLAMPS ON KNOCKOUTS 6) KITCHEN SINK REQUIRES VENT TO ROOF, SEE PLAN 7) STOPPED INSPECTION TO MANY ITEMS