Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM00666
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/16/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
05/13/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) DO NOT RE-CALL UNTIL CORRECTIONS ARE MADE | |
05/09/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0950*/ 1) ITEMS 2, 4 AND 5 FROM 5/7/03 INSPECTION NOT CORRECTED 2) NEXT FAILURE WILL INCUR RE-FEE | |
05/07/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) COIL STRAP MISSING AT SOUTH GABLE BRACE 2) 2ND FLOOR PLATES AT EXTERIOR WALLS REQUIRE 12" ON CENTER NAILING 3) TRUSS BLOCKING MUST BE NAILED THROUGH ROOF SHEATHING 4) INSTALL APPROVED ALTERNATE AT MISSED A.B.'S 5) FHA STRAP BOTTOM PLATE PLUMBING CUTS AT EXTERIOR |