Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/14/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 03/13/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) DOUBLE TOP PLATE NOT STAGGERED WEST WALL GARAGE PER CODE. ALSO EAST WALL GARAGE INTERIOR WALL 2) NAIL PROTECT PLUMBING WEST WALL 3) SHEER WALL REAR OF HOUSE NOT COMPLETELY NAILED PER SCHEDULE 4) STRAP DOUBLE TOP PLATE FRONT ENTRY WAY TO BEAM 5) REPLACE ALL H2.5'S AT DOUBLE TOP PLATE TO BOTTOM CORD OF TRUSS WITH STRAPS ON RSP4'S |