Permit: T03CM00592

Parcel: 141172140


Addresses:

10350 E ROYWOOD WY

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/14/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
03/13/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) DOUBLE TOP PLATE NOT STAGGERED WEST WALL GARAGE PER CODE. ALSO EAST WALL GARAGE INTERIOR WALL 2) NAIL PROTECT PLUMBING WEST WALL 3) SHEER WALL REAR OF HOUSE NOT COMPLETELY NAILED PER SCHEDULE 4) STRAP DOUBLE TOP PLATE FRONT ENTRY WAY TO BEAM 5) REPLACE ALL H2.5'S AT DOUBLE TOP PLATE TO BOTTOM CORD OF TRUSS WITH STRAPS ON RSP4'S