Permit: T03CM00570

Parcel: 140294270

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM00570

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/26/2003 FRAMING Approved IVRS - Inspection 0000*
03/24/2003 FRAMING Denied 1) NAIL SHEAR PANEL TO CONFORM WITH APPROVED DRAWINGS
03/21/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) ITEMS NOT CORRECTED
03/20/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) 1ST FLOOR LAV TRAP ARM EXCEEDS 42" AND WEIR HIGHER VENT 2) NO DWV WATER TEST 3) IMPROPER PEX COUPLING AT SERVICE ENTRANCE MORE THAN 1/16" FROM STOP 4) FLOOR JOIST NOT BEARING ON GLU LAM BEAM DINING ROOM AND HEADER 5) PEX NOT ALLOWED WITHIN 12" OF CAN LIGHT KITCHEN 6) NAIL PROTECT WIRES WITHIN 1 1/4' OF STUD SURFACE 7) 2ND FLOOR BOTTOM PLATE DOES NOT BEAR ON FLOOR-MANY PLACES 8) PLATES MUST BEAR ON HEADERS AND HEADERS ON TRIMMERS 9) PROVIDE SHEAR PANELS FRONT BEDROOM
03/17/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) COMPLETE LATH 1ST