Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/26/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 03/24/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) GARAGE POSTS NOT CLIPPED PER ENGINEER DETAIL AT BOTTOM 2) NO DWV WATER TEST 3) SHOWER NOT PROPERLY VENTED BELOW CENTER LINE OF DRAIN 4) PRVOIDE POSITIVE SHEAR TRANSFER AT BREAK IN KITCHEN SHEARWALL AT PANTRY 5) WATER HEATER "B" VENT REQUIRES DRAFT STOP AND 1" CLEARANCE TO COMBUSTIBLES 6) SHOWER VALVES NOT SECURE 7) HIP HANGER NOT NAILED 8) 2ND FLOOR SILL PLATES NOT NAILED AT 12" ON CENTER 25/S1-2 AND 26/S1-2 |