Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM00520
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/21/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
03/19/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) FIRESTOP COLUMN AT KITCHEN 2) FIRE BLOCK PLANT SHELVES 3) PROVIDE ENGINEERING REPAIR FOR BROKEN TRUSS | |
03/18/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NAIL ALL LADDER BLOCKS AT SHEAR WALLS 2) ALL H.D.'S NOT BOLTED TO SLAB 3) TWO P.A.'S AT EXT. STEM, ARE NOT IN BEDDED IN CONCRETE, NEED RETRO FIT 4) GABLE END BRACES, NEED BETTER (8' ON CENTER) CONNECTIONS 5) COMM. WIRE IN CLOSET BANG PLATE 6) 2 X 6 CUT AT WASHER 7) BROKEN TRUSS 8) GAS, DWV AND PLUMBING WATER-OK |