Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/11/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/10/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING OUTLET OFFICE 2) COMPLETE FRAMING DEN 3) REMOVE OLD EXISTING WIRING DEN/OFFICE 4) NOTES 6 & 8 FROM PREVIOUS |
|
| 09/14/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE 1" CLEARANCE COMBUSTIBLE MATERIALS WATER HEATER FLUE 2) FIRE BLOCK WH PLENIUM 3) DRIP LEG WATER HEADER 4) MISSING OUTLET BAY WINDOW 5) NO WATE TEST DWV SYSTEM 6) NAIL PROTECT 7) OVERSPAN CRIPPLES BEDROOM CLOSET 8) BLOCK TUB WALLS 9) SECURE 90 VENT THROUGH ROOF 10) CLOSETS NOT COMPLETED-EXISTING 11) BLOCK REGISTER 3 SIDES EXSTING CLOSETS 12) MISSING SMOKE DETECTORS BEDROOM AND HALLWAYS 13) PROVIDE GAS BOND 14) COMPLETE FRAMING BAY WINDOW |
|
| 09/08/2006 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED BY OWNER |
|
| 09/05/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ACCESS PHONE # ON MESSAGE WRONG PHONE # 245-6105 |