Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 01/27/2004 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 01/22/2004 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ NEED WIRE PROTECTOR ST. SEE CARPORT AND OTHER AREA. SCREWS IN BOX NOT ALLOWED. BOND METAL 4 SQUARE BOX. HAVE PLAN AVAILABLE. |
| 01/16/2004 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ LIGHTS INSTALLED IN CLOSETS MUST COMPLY WITH ART. 410, AS SHELVING WILL BE CONFIGURED. NOT READY - NEED A RE-CHECK BY ELECTRICAL BOXES AND STAPLES REMOVED. NEED MORE FHA STRAPS. RANGE 8-3 ROMEX IS RATED 40 AMPS. CHECK PLAN IF CIRCUIT IS TO BE 50 AMPS. SCREWS INSIDE PLASTIC BOXES, CODE VIOLATIONS. WILL NEED BOX FOR BATHROOM FIXTURE. |