Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM00355

Parcel: 14117005D

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM00355

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/21/2003 EXT METAL CLIPS/EXT SHEATHING Approved
03/20/2003 EXT METAL CLIPS/EXT SHEATHING Denied 1) 18/D1 NAIL OFF TOP OF SHEAR PANELS 8D'S AT 6" ON CENTER TO ROOF DECK BOTH SHEAR WALLS AT FRONT ENTRY #5 SHEARWALL 2) SHEARWALL GARAGE DETAIL 17/D1 PLYWOOD TRUSS FOR SHEAR OR SUPPLY INFO OF STRUCTUAL, H.D.'S ON GARAGE WALL CALL FOR EPOXY NOT KWIK BOLTS? 3) NAIL OFF SHEAR AT REAR SLIDINGDOOR 4) OPEN UP SHEATHING AT GARAGE LEDGER VERIFY A3.5 ARE NAILED 5) BLOCK AND NAIL ALL OSB TURNED PARALELL TO TRUSSES GARAGE ROOF 6) NAIL OFF ALL BLOCKS AT BEARING WALLS TO ROOF DECK 7) NEED TRUSS DRAWINGS 8) SECURE ALL TRUSS BRACING AND GABLE END BRACING, WITH NAILS IN SHEAR NOT WITH DRAWL
03/19/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
03/17/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*