Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM00355
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/21/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
03/20/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) 18/D1 NAIL OFF TOP OF SHEAR PANELS 8D'S AT 6" ON CENTER TO ROOF DECK BOTH SHEAR WALLS AT FRONT ENTRY #5 SHEARWALL 2) SHEARWALL GARAGE DETAIL 17/D1 PLYWOOD TRUSS FOR SHEAR OR SUPPLY INFO OF STRUCTUAL, H.D.'S ON GARAGE WALL CALL FOR EPOXY NOT KWIK BOLTS? 3) NAIL OFF SHEAR AT REAR SLIDINGDOOR 4) OPEN UP SHEATHING AT GARAGE LEDGER VERIFY A3.5 ARE NAILED 5) BLOCK AND NAIL ALL OSB TURNED PARALELL TO TRUSSES GARAGE ROOF 6) NAIL OFF ALL BLOCKS AT BEARING WALLS TO ROOF DECK 7) NEED TRUSS DRAWINGS 8) SECURE ALL TRUSS BRACING AND GABLE END BRACING, WITH NAILS IN SHEAR NOT WITH DRAWL | |
03/19/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000* | |
03/17/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000* |