Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
04/16/2003 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
03/25/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*RFI ADDENDUM 3 REQUIRES ENGINEERS SEAL & SIGNATURE.
03/21/2003 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection 0999*BOND BEAM REQUIRED @ LEDGER HEIGHT.
03/18/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
2ND LIFT W/BOND BEAM.
03/13/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*stem wall ok.
02/28/2003 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection 0999*PROVIDE RFI FOR CHANGE IN SLAB DOWELS SEE DETAIL 3/7.
02/25/2003 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection 0999*1.) CLEAN DIRT OUT OF GROUT CELLS.
2.) IMPROPER LAP LENGTH OF VERTICAL REINFORCEMENT IN EAST PARTY WALL. 20" REQUIRED.