Permit: T03CM00302

Parcel: 11307086A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
08/03/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*/ 1) FLOOR SINKS AND DRAINS BLOCKED OUT OR INSTALLED OK TRAP PRIMERS-OK 2) CONTRACTORS TO WRAP ALL ABS RISERS PASSING THRU CONCRETE
07/31/2003 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*/ 1) ABS DWV UNDERGROUND-OK. WATER TEST ON RISER TO TEN FEET-OK. GREASE TRAP-OK. OK TO BACKFILL 2) NEED TO SEE FLOOR SINKS, FLOOR DRAINS AND TRAP PRIMERS
07/30/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) AN ABS BLAKE TEE IS LISTED TO BE USED IN THE VERTICAL POSITION, ABOVE GRADE, AS A SURFACE CLEANOUT 2) SEE INSTALLATION STANDARD FIVE-94 UPC 316.1.5 FEMALE ABS FITTINGS SHALL BE IN AN ACCESSIBLE LOCATION 3) OK TO COVER ALL OTHER AREAS 4) GREASE TRAP OK