Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM00274
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/10/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
04/09/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) NEED DRAG STRUTS 2) NEED 16 ON CENTER STUDS IN REAR GARAGE SHEAR WALL 3) REPLACE FIREBLOCK OVER GARAGE PEDESTRIAN DOOR 4) BANG PLATE WIRES OVER MASTER DOOR AND AT TOP PLATE OF NORTH AND WEST MASTER CLOSET 5) NEED RED HEAD ON NORTH LIVING WALL 7) NEED DWV |