Permit: T03CM00264

Parcel: 13316030E

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/14/2003 FRAMING Approved IVRS - Inspection 0000*SEE PREVIOUS NOTES REGARDING MECH. DUCT PENETRATIONS MAINTAIN 1 HR. RATING W/ALL PENETRATION ELEC. ETC.
05/13/2003 FRAMING Denied IVRS - Inspection 0999*NEED BOTH SIDES OF 1HR WALL ALSO GET PERMIT FOR MECH. WORK NEED DAMPERS IN WALL. CHECK OPENING.
05/02/2003 FRAMING Denied IVRS - Inspection 0999*GET REVISION FROM ARCHITECT SHOWING WHAT YOU PROPOSE TO DO OR BUILD PARTITION ACCORDING TO PLANS.
04/24/2003 FRAMING Denied IVRS - Inspection 0999*INSTALLATION DOESN'T MATCH THE APPROVED PLANS. PLANS SHOW EXTENDING THE WALL TO THE ROOF DECK.
ALSO PLANS CALL FOR SCREW PATTERN @ 8" AT PERIMETER @ 12" IN THE FIELD.
POST SUITE #236 IN HALLWAY.