Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
02/09/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*HOME OWNER HAS INSTALLED SOME UNORTHODOX PLUMBING, HOWEVER I FEEL THE SYSTEM SHOULD OPERATE OK. OWNER IS AWARE FOR MINOR CODE INFRACTIONS AND IS WILLING TO LIVE WITH THEM.
2.) OK TO COVER WALLS TRANSITION FITTINGS OK OWNER WATER TESTED ABS COPPER OK.
02/06/2003 PLUMBING - INTERMEDIATE Denied 1.) WET VENT WASHER ABOVE TUB.
NO HORIZONTAL DRAIN PIPE ALLOWED ON WET VENT 2" TRAP ON WASHER WET VENTED SECTION UNDERSIZED STAND PIPE RECEPTOR TO BE 18"-30" LONG WASHER TRAP TO BE ROUGHED IN 6" -18" AFF.
CHANGES OF DIRECTION EXCEEDING 135 REQUIRE ADDITIONAL CLEANOUT.
2.) SOME WORK COVERED BEFORE INSPECTION.