Permit: T03CM00259

Parcel: 10922022B


Addresses:

3170 N CRAYCROFT RD

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
08/11/2003 ROOF NAILING Approved IVRS - Inspection 0000*
07/31/2003 ROOF NAILING Denied IVRS - Inspection 0999* 1) THE LARGE CRICKET IS INADEQUATELY FROMED ON EITHER SIDE OF ITS RIDGE. ALMOST BROKE THROUGHT IT WHILE WALKING ON IT. ALSO THE EAST END OF THIS CRICKET IS NOT NAILED OFF. 2) 1 SHEET OF OSB IS NOT NAILED OFF ON THE NORTH ROOF PLANE, 2 ROWS DOWN FROM THE RIDGE. 3) ROOF SHEATHING AT THE RIDGE, THAT IS LESS THAN 24" WIDE MUST HAVE H CLIPS.