Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM00246
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/14/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
03/13/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) PROTECT ALL ELECTRICAL WIRES WITHIN 1 1/4" FROM EDGE OF STUD/DBL TOP PLATE 2) REMOVE SCREEN FROM DRYER WENT T-TOP 3) DWV'S FAILED WATER TEST 4) NAIL PROTECT DRYER VENT WITH A 16 5) IF COUNTER TOP AT KITCHEN PONY WALL EXTENDS MORE THAN 6" OUTLET MUST BE REMOVED 6) COMPLY WITH DETAIL 8 A8A 7) LATH NOT READY |