Permit: T03CM00232

Parcel: 121010160

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
08/16/2004 ELECTRIC - FINAL Approved IVRS - Inspection :*
07/13/2004 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*/ 1) ROOF: USE APPROVED FITTING FOR SEAL TITE AND SUPPORT UP OFF ROOF 2) GROUNDING EQUIPMENT CONDUCTOR TO BE GREEN ENTIRE LENGTH AND CORRECT SIZE PER 250.119 + 250.122 3) TIGHTEN RECEPTACLE BOX 4) OK TEMP POWER
07/07/2004 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*/ 1) HOOD TO USE APPROVED CONNECTOR NOT A BUSHING 2) AN APPROVED EXTENDER RING IS NEEDED WHERE DEVICE IS IN COMBUSTIONS 3) SWITCHES TO BE GROUNDED 4) WATER HEATER TO HAVE DISCONNECTING MEANS AND TIGHTEN FITTING 5) LABEL BREAKERS 6) FINISH OUTSIDE SOFFITS 7) BREAKER AMPACITY FOR NM CABLE TO BE AS PER 336.26 8) CLEAN BUSS OF FOREIGN MATERIAL