Permit: T03CM00180

Parcel: 141300540

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM00180

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/11/2003 FRAMING Approved IVRS - Inspection 0000*
03/07/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) SECURE TUB SURROUNDS NEED BACKING 2) 2ND FLOOR TOILET VENT CANNOT COME OFF WITH A 90 DEGREE ELBOW BELOW FLOOR RIM (SEE LOT 156 IS DONE CORRECTLY) 3) CUT HOLE FOR DRYER VENT BIGGER, VENT IS RESTRICTED 4) CHASE REAR WALL 1ST FLOOR SECURE STUD, AT 3" VERTICAL PIPE STRAP A.B.'S 5) ACCESS PANEL FOR JACCUZI TUB MOTOR 6) REMOVE GAS LINES UNDER UNITS 7) METAL CEILING WATER HEATER FLU FIRE/STOP 8) PLEASE CHECK TRUSS DRAWINGS FOR LATERAL BRACES AT ROOF TRUSSES OR LEAVE TRUSS DRAWINGS