Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM00180
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/11/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
03/07/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SECURE TUB SURROUNDS NEED BACKING 2) 2ND FLOOR TOILET VENT CANNOT COME OFF WITH A 90 DEGREE ELBOW BELOW FLOOR RIM (SEE LOT 156 IS DONE CORRECTLY) 3) CUT HOLE FOR DRYER VENT BIGGER, VENT IS RESTRICTED 4) CHASE REAR WALL 1ST FLOOR SECURE STUD, AT 3" VERTICAL PIPE STRAP A.B.'S 5) ACCESS PANEL FOR JACCUZI TUB MOTOR 6) REMOVE GAS LINES UNDER UNITS 7) METAL CEILING WATER HEATER FLU FIRE/STOP 8) PLEASE CHECK TRUSS DRAWINGS FOR LATERAL BRACES AT ROOF TRUSSES OR LEAVE TRUSS DRAWINGS |