Permit: T03CM00146

Parcel: 116213870


Addresses:

458 S STEPHANIE LP

Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Date Description Inspector Results Comments
11/20/2003 SHEET ROCK NAILING Approved IVRS - Inspection 0000*
11/18/2003 SHEET ROCK NAILING Not ready for Inspection IVRS - Inspection 0000*/ 1) CANCELLED
11/17/2003 SHEET ROCK NAILING Denied IVRS - Inspection 0999*/ 1) SAG RESISTANT REQUIRED AT LIDS AT 24" ON CENTER
11/14/2003 SHEET ROCK NAILING Denied IVRS - Inspection 0999*/ 1) MAXIMUM 8" NAIL SPACING ON WALLS LIDS 7", 12" WITH SCREWS 2) COMPLETE 5/8" UNDER STAIR NAILING 3) SAG RISISTANT DRYWALL REQUIRED AT ALL 24" ON CENTER LIDS (EXCEPT EXTERIOR SOFFITS) 4) COMPLETE NAILIN IN CLOSET NEAR ENTRY AND LID IN HALL 5) RENAIL TOO CLOSE TO EDGES AND OVER PENETRATED 6) NAIL EDGES AT UPPER EXTERIOR SOFFITS 7) NAIL EDGES THROUGHOUT 8) GARAGE PLAN INDICTAES TWO LAYERS OF TYPE C AT LID 9) PLAN INDICATES 1/2" TYPE C AT WALL TO ROOF SHEATHING 10) SOME OF THE UPPER EXTERIOR WALLS ARE TYPE X AND SOME ARE NOT ?