Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/20/2003 |
SHEET ROCK NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 11/18/2003 |
SHEET ROCK NAILING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CANCELLED |
| 11/17/2003 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) SAG RESISTANT REQUIRED AT LIDS AT 24" ON CENTER |
| 11/14/2003 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) MAXIMUM 8" NAIL SPACING ON WALLS LIDS 7", 12" WITH SCREWS 2) COMPLETE 5/8" UNDER STAIR NAILING 3) SAG RISISTANT DRYWALL REQUIRED AT ALL 24" ON CENTER LIDS (EXCEPT EXTERIOR SOFFITS) 4) COMPLETE NAILIN IN CLOSET NEAR ENTRY AND LID IN HALL 5) RENAIL TOO CLOSE TO EDGES AND OVER PENETRATED 6) NAIL EDGES AT UPPER EXTERIOR SOFFITS 7) NAIL EDGES THROUGHOUT 8) GARAGE PLAN INDICTAES TWO LAYERS OF TYPE C AT LID 9) PLAN INDICATES 1/2" TYPE C AT WALL TO ROOF SHEATHING 10) SOME OF THE UPPER EXTERIOR WALLS ARE TYPE X AND SOME ARE NOT ? |