Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/29/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/27/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) FIRE STOPPING 2ND FLOOR SHAFT 2) SHIM HEADERS. 3) SEAL FLOOR/CEILING PENETRATIONS. 4) DUER BLOCKING. |
| 10/21/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) BLOCK OUT FURNACE AT LID 2) STRAP PLATE AT DRYER VENT 3) SHIM HEADER AT GARAGE WINDOW REAR SLIDER ALTERNATE AT GARAGE POST TO BEAM 4) FIRE STOP TOP PLATE IN FURNACE ROOM 5) ANCHOR STAIR PER DETAIL 6) INSTALL GPC OR APPROVED 7) SEAL FLOOR PENETRATIONS 8) INSTALL POST AT DINING EXTERIOR WALL 9) NAIL PLATE IN FURNACE THROUGHOUT 10) SMOKE DETECTOR IN OFFICE/BR 11) NAIL PLATE WASTE IN FURNACE ROOM, NEAR FRONT DOOR, HALL BATH 12) TEST WASTE 13) SUPPORT WASTE FROM 2ND FLOOR 14) 1" CLEARANCE AT FURNACE FLUE 15) SUPPORT DUCT NEAR FIREPLACE 16) INSTALL HEAT SHIELD AND BLOCK OUT FIRE STOP SPACER PER DETAIL |