Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM00123
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/04/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
03/03/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) FRONT ENTRY, H2.5 TIE TO WALL THAT'S TIED BELOW AT BOTTOM/TOP PLATES 2) WIND BRACES 25'-0" ON CENTER 3) SECURE OVERFRAMING VERT SUPPORTS, STRAP GABLE END FLAT STUDS 4' ON CENTER CHECK LEDGER NAILING 4) MISSED NAILING EAST CC PLY AT FACIA, PUT BLOCKS UNDER OSB TURNED OPPOSITE TRUSSES AT RIDGE EAST 5) NEED TRUSS DRAWINGS 6) BLOCK UNDER 3 PT BEARING BEFORE LOADING 7) INSTALL LATERAL BRACES |