Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/27/2005 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 05/25/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 01/21/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INTERMEDIATE PLUMBING DWV REQUIRES A WATER TEST TO ROOF 2) SEWER PIPE FROM ADDITION TO EXISTING SEWER OK TO COVER EXCEPT CONNECTION AT SEWER NOT MADE. DO NOT COVER SEWER CONNECTION 3) POTABLE WATER SYSTEM NOT COMPLETE 4) WASTE VENT MUST EXHAUST OUT ROOF 5) TOILET VENT MUST BE 2" THRU ROOF 6) SUPPORT HORIZONTAL DWV AT 4' ON CENTER |