Inspection Status: Approved
Inspection History: STORMWATER INSTALL OF CONTROLS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/29/2004 | STORMWATER INSTALL OF CONTROLS | Approved | INSTALLATION OF CONTROLS IS COMPLETE. | |
| 06/21/2004 | STORMWATER INSTALL OF CONTROLS | Correction Required | 1. COMPLETE SILT FENCE INSTALLATION AT SW CORNER OF PROJECT. | |
| 06/14/2004 | STORMWATER INSTALL OF CONTROLS | Denied | 1. COMPLETE SILT FENCE INSTALLATION AT SW CORNER OF PROJECT. 2. MAINTAIN EXISTING SILT FENCE AND CORRECT DEFICIENCIES. |
|
| 06/04/2004 | STORMWATER INSTALL OF CONTROLS | Denied | 1. FUTURE PHASE II SITE IS BEING USED AS SUPPORT FOR PHASE I OPERATIONS. STORMWATER CONTROLS ARE REQUIRED FOR PHASE II AT THIS TIME. 2. SILT FENCING NORTH OF CALLE LA PAZ IS BERMED, BUT IT IS NOT KEYED IN PER THE SPECIFICATIONS. A COMPACTED BERM AGAINST THE BOTTOM OF THIS FENCE WILL HELP TO PROVIDE CONTAINMENT. BROKEN FENCE STAKES AND SPLICED AREAS NEED MAINTENANCE. 3. SILT FENCING SOUTH OF CALLE LA PAZ IS KEYED IN, HOWEVER SOME SILT FENCING IS NOT YET IN PLACE. |
|
| 06/02/2004 | STORMWATER INSTALL OF CONTROLS | Denied | 1. I MET WITH BFL CONSTRUCTION CO. SUPERINTENDENT RONALD HERRING (488-6273). MAGNUM PAVING IS THE GRADING CONTRACTOR. ROUGH GRADING HAS OCCURRED ON THE ENTIRE SITE. 2. SILT FENCING HAS BEEN IN-CORRECTLY INSTALLED ON THE NORTHERN PORTION OF THE SITE AT THE SOUTH, WEST AND NORTH PERIMETERS. 3. SCE ON THE NORTH IS IN PLACE, SCE ON SOUTH IS BEING INSTALLED. 4.INFORMED MR. HERRING THAT SWPPP CONTROLS ARE TO BE INSTALLED PRIOR TO ANY GRADING ACTIVITY. |