Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03BU03088

Parcel: 128111880


Addresses:

4842 E PASEO LUISA

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/01/2004 FRAMING Approved IVRS - Inspection :*
05/25/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) REVISED PLAN DATED 5/19/04 SHOWS PURLINS 6' ON CENTER 2) REVISE PLAN SHOWS SLOPE OF ROOF 90 DEGREE TO ASBUILT 3) ROOF DECK NOT SCREWED OFF PER PLAN. ALL ENDS REQUIRE 6 SCREWS. ALL SIDES #14 SCREWS 18" ON CENTER 4) REVISE YOUR PLAN OR BUILD PER PLAN