Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/01/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/25/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) REVISED PLAN DATED 5/19/04 SHOWS PURLINS 6' ON CENTER 2) REVISE PLAN SHOWS SLOPE OF ROOF 90 DEGREE TO ASBUILT 3) ROOF DECK NOT SCREWED OFF PER PLAN. ALL ENDS REQUIRE 6 SCREWS. ALL SIDES #14 SCREWS 18" ON CENTER 4) REVISE YOUR PLAN OR BUILD PER PLAN |