Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03BU02830


Addresses:

446 N CAMPBELL AV


Inspection Status: Approved

Inspection History: GRADING - FINAL

Permit Number - T03BU02830

Inspection Description - GRADING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/04/2005 GRADING - FINAL Approved John approved this today as. May 16th 2005 computer was not updated
05/16/2005 GRADING - FINAL Approved
04/11/2005 GRADING - FINAL Denied SEE NOTE #10 OF PREVIOUS INSPECTION.
PROVIDE (2) TYPE "B" POST BARRICADES AT 5' ON CENTER AT EACH END OF BICYCLE PATH ON SOUTH SIDE OF PROJECT AS SHOWN ON THE PIA AND GRADING PLANS.
04/07/2005 GRADING - FINAL Denied DENIED, ALL ITEMS ON THE ESTABLISHED PUNCH LIST HAVE NOT BEEN COMPLETED.
03/02/2005 GRADING - FINAL Denied 1. PROVIDE REVISED GRADING AND DEVELOPMENT PLANS FOR REVIEW AND APPROVAL BY THE CITY OF TUCSON ENGINEERING AND ZONING DIVISIONS THAT SHOWS ALL REVISIONS AND MODIFICATIONS.
2. COMPLETE ALL ROOF DOWNSPOUT EXTENSIONS PER DETAIL J, PAGE 2.
3. PROVIDE A TYPE 2 SIDEWALK SCUPPER NEAR THE NORTHEAST CORNER OF BLDG. 2, AS SHOWN ON THE PLAN, OR PROVIDE REVISED AND APPROVED GRADING AND DEVELOPMENT PLANS.
4. PROVIDE REVISED AND APPROVED GRADING AND DEVELOPMENT PLANS SHOWING THE MODIFICATIONS TO THE BICYCLE PARKING.
5. PROVIDE THE RETAINING WALL AT THE SOUTHEAST CORNER OF BUILDING 2. KEYNOTE 26, PAGE 2.
6. PROVIDE 42" HIGH BARRICADE RAILING EAST OF BUILDING 3 KEYNOTE 25, PAGE 2.
7. ADDRESS THE SIDEWALK ACCESS TO NORRIS AVENUE BETWEEN BUILDINGS 3 & 4.
8. ADDRESS THE STEEP SLOPE SOUTHEAST OF BLDG 4. DETAIL K, SHEET 4.
9. PROVIDE THE RETAINING WALL AND SLOPE TREATMENT AT THE SOUTHWEST CORNER OF BUILDING 1. SEE KEYNOTE 26 AND TYPICAL SLOPE TREATMENT NOTE.
10. PROVIDE (2) BOLLARDS AT BOTH THE EAST AND WEST ENDS OF THE PAVED BICYCLE PATH ON THE SOUTH PERIMETER OF SITE. NO KEYNOTE WAS SHOWN ON THE PLAN.
11. REPAIR THE DAMAGED CURB AT THE SOUTHWEST CORNER OF THE SOUTHWEST GAS FACILITY AND AT THE INLET TO THE EXISTING CURB INLET ON THE SOUTH PERIMETER.
12. CLEANUP AND REMOVE ALL CONSTRUCTION MATERIAL AND DEBRIS AT THIS SITE.
13. PROVIDE AN ARIZONA REGISTERED PROFESSIONAL ENGINEER'S CERTIFIED INSPECTION REPORT FOR THE DRAINAGE AND DETENTION/RETENTION FACILITIES. SEE GRADING PLAN PAGE 1, MAINTENANCE OF DETENTION/RETENTION FACILITIES NOTE 2.
04/06/2004 GRADING - FINAL Not ready for Inspection 1. UNDERGROUND RETENTION/DETENTION BASIN IS APPROXIMATELY 90% COMPLETE. WESTERN TECH WILL BE PERFORMING COMPACTION TESTS ON BACKFILL AND PROVIDE RESULTS TO THE CONTRACTOR AND DSD REVIEW.
04/06/2004 GRADING - FINAL Not ready for Inspection Not ready for inspection.
1. Under ground retention/detention basin has been completed. Western Tech was on site and performing their compaction test.
2. I informed Lyal with Triumph not to call in another inspection until he has completed additional drainage channels and pipes to tie into the underground retention/detention basin.
04/01/2004 GRADING - FINAL Not ready for Inspection 1. UNDERGROUND RETENTION/DETENTION BASIN IS APPROXIMATELY 90% COMPLETE. WESTERN TECH WILL BE PERFORMING COMPACTION TESTS ON BACKFILL AND PROVIDE RESULTS TO THE CONTRACTOR AND DSD REVIEW.
03/30/2004 GRADING - FINAL Denied C OF O DENIED.

1. SITE NOT READY FOR INSPECTION DUE TO NEEDED INSPECTION FOR BACKFILL AND COMPACTION PER APPROVED PLANS.
03/26/2004 GRADING - FINAL Not ready for Inspection PARTIAL APPROVAL FOR R/D BASIN EXCAVATION LINED WITH FILTER FABRIC AND 2.5' BEDDING OF PEA GRAVEL. WEST END EXCAVATION IN PROGRESS FOR FULL 240' LENGTH.
03/23/2004 GRADING - FINAL Not ready for Inspection PARTIAL APPROVAL FOR 9.5 X 10' X 240' R/D BASIN EXCAVATION.
03/16/2004 GRADING - FINAL Not ready for Inspection PARTIAL APPROVAL FOR UNDERGROUN R/D BASIN EXCAVATION. CALL FOR INSPECTION WHEN FILTER FABRIC IS INSTALLED.