Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/05/2008 | GRADING - FINAL | Partial Approval | email and research time | |
03/04/2008 | GRADING - FINAL | Partial Approval | MET WITH ROBERT BOLLIN 714-504-1982 AND WALKED SITE PREVIOUS PUNCHLIST ITEMS HAVE BEEN MOSTLY ADDRESSED SITE IS MISSING 5 H/C PARKING SPACES ROOF DRAINS ARE NOT AS INDICATED ON PLANS THERE ARE 2 BUBBLER BOXES OR CATCH BASINS NOT DEPICTED ON PLANS THIS IS AN OUTSTANDING GRADING PERMIT |
|
07/25/2005 | GRADING - FINAL | Denied | FINAL GRADING PUNCH LIST: 1) CLEAN OUT SEDIMENT AND CONSTRUCTION DEBRI FROM BOTH CATCH BASIN/ROOF DRAINS LOCATED WITHIN THE PARKING AREA ON THE EAST SIDE OF THE BUILDING. 2) COMPLETE PEDESTRIAN STRIPING AND DIRECTIONAL ARROWS AS SHOWN ON PLANS. 3) PROVIDE HANDICAP GROOVES WITHIN CONCRETE PEDESTRIAN PATHWAYS AS SHOWN ON PLANS. 4) PROVIDE 12" SINGLE CURB AS OPPOSED TO 6" SINGLE CURB LOCATED TO THE EAST OF THE NORTHEAST ENTRANCE. REPLACE CURB OR PROVIDE C.O.T. REVISED APPROVED PLANS INDICATING 6" CURB. 5) PROVIDE TRASH ENCLOSURE ENTRANCE DEMENSIONS AND BALLARDS AS APPROVED IN THE C.O.T. STANDARD CODES NO.6-01.0 6) COMPLETE LANDSCAPING ALONG THE NE CORNER OF THE SITE ALONG THE SIDEWALK. PROVIDE 6" DEPRESSED LANDSCAPING JUST NORTH OF THE SOUTHERN ENTRANCE ALONG WILMOT. 7) COMPLETE ALL CURB AND ASHPALT REPAIRS AS NOTED ON PLANS. 8) COMPLETE INSTALLATION OF WHEEL STOPS LOCATED IN THE VERY SOUTH WEST CORNER OF THE PROJECT. 9) PROVIDE POSITIVE DRAINAGE IN THE VERY NW CORNER OF THE SE PARKING AREA. |
|
07/18/2005 | GRADING - FINAL | Not ready for Inspection | SPOKE WITH THE SUPERINTENDENT, (RICK BOVIEINGTON 400-7380), REGARDING FINAL GRADING INSPECTION. HE EXPLAINED THE REVISED GRADING PLAN WAS MISSING AND THAT HE WOULD LOCATE THE PLAN TO USE FOR AN INSPECTION ON THURSDAY, JULY 21ST. |