Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T03BU02637
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/20/2003 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection 0000* | |
10/16/2003 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection 0999* 1) FOOTINGS ARE TO BE 18" X 18" X 12" DEEP. 2) REBAR MAY NOT CONTACT EARTH (YOUR VERTICAL SUPPORTS ARE IN DIRT). 3)YOU NEED 2 #4 EACH WAY- YOU MAY DOUBLE UP THE #3'S YOU HAVE IN ORDER TO MEET REQUIRMENTS. 4) IF YOU ARE USING 4 X 8 BEAM PER PLAN THEN YOUR POSTS MY NOT EXCEED 11' O.C. IF YOU ARE USING 4 X 10 BEAM TO MATCH EXSISTING PORCH- THEN YOU MUST REVISE PLAN. |