Permit: T03BU02637

Parcel: 141137360


Addresses:

9109 E ARBAB CT


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T03BU02637

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
10/20/2003 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
10/16/2003 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999* 1) FOOTINGS ARE TO BE 18" X 18" X 12" DEEP. 2) REBAR MAY NOT CONTACT EARTH (YOUR VERTICAL SUPPORTS ARE IN DIRT). 3)YOU NEED 2 #4 EACH WAY- YOU MAY DOUBLE UP THE #3'S YOU HAVE IN ORDER TO MEET REQUIRMENTS. 4) IF YOU ARE USING 4 X 8 BEAM PER PLAN THEN YOUR POSTS MY NOT EXCEED 11' O.C. IF YOU ARE USING 4 X 10 BEAM TO MATCH EXSISTING PORCH- THEN YOU MUST REVISE PLAN.