Permit: T03BU02624

Parcel: 141173160

Inspection Status: Approved

Inspection History: POOL/SPA FINAL/BARRIER

Permit Number - T03BU02624

Inspection Description - POOL/SPA FINAL/BARRIER

Inspection Status - Approved

Date Description Inspector Results Comments
12/10/2003 POOL/SPA FINAL/BARRIER Approved IVRS - Inspection 0000*
12/03/2003 POOL/SPA FINAL/BARRIER Not ready for Inspection IVRS - Inspection 0000*/ 1) NEED BOND CONNECTORS ON ALL FENCE CONNECTIONS 2) BOND AIRATOR 3) JACCUZI, LIGHT PUT A COPPER CONNECTOR #8 CU, ON #8 CU WIRE ATTACH TO WET NICHE FIXTURE. LEAVE COMPOUND OFF CONNECTION 4) SECURE ALL SEAL TITE CONDUIT TO WALL, ALL CONDUIT OFF THE GROUND